Home » Abstracts » PTM & Glycoproteomics » Improved sensitivity and throughput for low-input phosphoproteome using short monolithic columns

Improved sensitivity and throughput for low-input phosphoproteome using short monolithic columns

Author(s)

  • Felix Schneidmadel | Uniklinikum Jena, Functional Proteomics | Friedrich-Schiller-Universität, 07747, Jena, Germany
  • Yue Yang | Uniklinikum Jena, Functional Proteomics | Friedrich-Schiller-Universität, , jena, Germany
  • Goran Mitulovic | Bruker Switzerland AG | Industriestasse 26, 8117, Fällanden, Switzerland
  • Mario Mirabelli | Bruker Switzerland AG | Industriestasse 26, 8117, Fällanden, Switzerland
  • Petra Martinovich | Bruker Daltonik GmbH & Co KG | Fahrenheistrasse 4, 28359, Bremen, Germany
  • Florian Busch | Bruker Switzerland AG | Industriestasse 26, 8117, Fällanden, Switzerland
  • pierre-olivier Schmit | Bruker France SAS | 34, rue de l'industrie , 67160, Wissembourg, France
  • Manuel Chapelle (Presenting Author) | Bruker France SAS | 34, rue de l'industrie, 67160, Wissembourg, France
  • Benoit Fatou | Bruker France SAS | 34, rue de l'industrie, 67160, Wissembourg, France
  • Florian Meier | Uniklinikum Jena, Functional Proteomics | Friedrich-Schiller-Universität, 07747, Jena, Germany

Abstract

By enabling to quantify thousands of phosphorylation events in a complete proteome, Mass Spectrometry (MS)-based phosphoproteomics has become a valuable approach for cellular signaling studies. However, sensitivity is critical when the workflow relies on reduced amounts of material (e.g. when using FACS-sorting or Laser-Capture Microdissection). In this study we evaluate if the use of short monolithic columns, instead of the standard bead-packed ones, can improve sensitivity without compromising throughput.
Phosphopeptides were enriched from 20 µg of HeLa cell lysate following the µPhos protocol (Oliinyk et al.). The peptides were then separated using a nanoflow liquid chromatography system (Bruker), employing either an in-house packed 15-cm column with an integrated emitter (75 µm ID, Dr. Maisch) or a 15-cm monolithic column with a 10 µm emitter (75 µm ID, Bruker). Data were acquired on a trapped ion mobility mass spectrometer (Bruker timsTOF Ultra2) in dia-PASEF mode and processed with Spectronaut (v19.5) in ‘directDIA+’ mode.
At a sample load equivalent to 5 µg of protein input, we identified approximately 27,800 phosphosites with the packed column and 25,500 with the monolithic column. As the input amount decreased, the monolithic column outperformed the packed column. With a 50 ng input, we identified around 1,700 phosphosites and 680 Class I sites using the monolithic column, compared to 1,100 phosphosites and 400 Class I sites with the packed column.